ENGINEERING DATA SHEET D
RELAY - LATCH
2 PDT, 1 AMP

Polarized, latching hermetically sealed relay
Contact arrangement 2 PDT
Alternative pulsing of coils will transfer contacts
Meets the requirements of MIL-PRF-39016
Qualified to CECC16101-024
SCC3602/019

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

1 Amp / 28 Vdc
Weight 4 grams max
Dimensions of case 12.8mm x 10.4mm x 6mm
Hermetically sealed, corrosion protected metal can.

CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
Contact rating per
pole and load type
Load Current in Amps
@28Vdc
100,000 cycles
100,000 cycles
100,000 cycles
1,000,000 cycles
resistive load
inductive load (200mH)
lamp load
low level (30ľA/30mV)
1
0.2
0.1
-
100 cycles
resistive overload 2
Esterline-Leach International
  www.leachintl.com
North America
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA

Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Europe, SA
2 Rue Goethe
57430 Sarralbe
France

Tel: (33) 3 87 97 98 97
Fax: (33) 3 87 97 84 04
Asia-Pacific Ltd.
20/F Shing Hing Commercial Bldg.
21-27 Wing Kut Street
Central, Hong Kong

Tel: (852) 2 191 2886
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component.
Date of issue: 3/06 - 9 - Page 1 of 4