ENGINEERING DATA SHEET 065*I
RELAY - LATCH
2 PDT, 0.5 AMP

Polarized, latching hermetically sealed relay
Contact arrangement 2 PDT
Alternative pulsing of latch or reset coil will transfer contacts
Meets the requirements of
Qualified to
MIL-PRF-39016/47
CECC16101-026

PRINCIPLE TECHNICAL CHARACTERISTICS


Contacts rated at

0.5 Amp / 28 Vdc
Weight 2 grams max
Dimensions of case 14.6mm x 8.8mm x 4.3mm max
Hermetically sealed, corrosion protected metal can.

CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
Contact rating per
pole and load type
Load Current in Amps
@28Vdc
100,000 cycles
100,000 cycles
1,000,000 cycles
resistive load
inductive load (200mH)
low level (30ľA/30mV)
0.5
0.1
-
100 cycles
resistive overload 1